The Titan dust sensor is the most advanced dust sensor on the market.
The Titan has four (4) dust channels, instantaneous and 3 rolling average channels.
The sensor handles all of the rolling average calculations as well as all alarming functions for all dust channels, including alarm delays.
The rolling average period and alarm setting for each channel is independently configurable.
All you have to do is read the data registers with either Modbus TCP or on one of the two RS485 port using Modbus RTU.
Team the Titan with one of our interface controllers and you have one of the most powerful compliance and diagnostic tools on the market.
The Interface Controller can store and back-up data to a USB drive so you can easily grab the history to help identify process changes or use the data to EPA MACT reporting.
| Parameter | Description / Value |
|---|---|
| Measurement Principle | Dynamic Induction |
| Measurement Range |
Detection Limit < 0.1 mg/m3 Max Several g/m3, depending on conditions |
| Enclosure | Stainless Steel (IP65 / Nema 4X) |
|
Communication Interfaces |
2 x serial communications RS485 1 x Ethernet Port |
| Communication Protocols | Modbus RTU & Modbus TCP |
| Analog Output | With Sentinel or eSentry Unit |
| Dust Channels |
Instantaneous (1-sec Avg) and 3 RA dust channels |
| Alarming | Alarm limits and delays for all dust channels |
| Automated Self-Checks |
Electronic Drift Check (EDC) Rod Isolation Check (RIC) * * US Patent 9482706B2 |
| Parameter | Description / Value |
|---|---|
| Measurement Range |
Detection Limit < 0.1 mg/m3 Max Several g/m3, depending on conditions |
| Enclosure | Stainless Steel (IP65 / Nema 4X) |
| Weight |
7.0 lbs (3.2 kg) (without the rod) |
|
Dimensions (without rod) |
7" x 11" x 5" 178mm x 280mm x 127mm (W x H x D) |
| Ambient Temperature | -40 C to +70 C (-40 F to 158 F) |
| Power Supply | 24 VDC |
| Power Consumption | Less than 5 Watts |
|
Communication Interfaces |
2 x serial communications RS485 1 x Ethernet Port |
| Communication Protocols | Modbus RTU & Modbus TCP |
| Process Temperature |
Default 200 C (392 F) Optionally up to 1600 F (871 C) |
| Process Pressure | Default 3000 psi (20684 kPa) |
| Process Humidity | Max 95% RH (non-condensing) |
| Self-Checks | Automated |
| Self-Check Functions |
Electronic Drift Check (EDC) Rod Isolation Check (RIC) (US Patent 9482706B2) |