919-790-9090
3208 Spottswood St, STE 106, Raleigh, NC 27615 MAP
sales@b3systems.com

Process Dust Sensor

Process Dust Sensor

Atlas Dust Sensor

The Atlas dust sensor has two (2) dust channels, instantaneous and 2 rolling average channels. This is a new line... The sensor handles all of the rolling average calculations as well as all alarming functions for all dust channels, including alarm delays. Each rolling average periods and alarm setting for each channel is independently configurable. All you have to do is read the data registers.

Team the Atlas with one of our interface controllers and you have one of the most powerful compliance and diagnostic tools on the market. The Interface Controller can store and back-up data to a USB drive so you can easily grab the history to help identify process changes or use the data to EPA MACT reporting.

Features

Parameter Scout Atlas Titan

Measurement Principle

Dynamic Induction
Detection Limit  < 0.1 mg/m3
Maximum Range Several g/m3, depending on conditions
Enclosure Stainless Steel (IP65 / Nema 4X)
Comm Ports
RS485 Ports
Ethernet

0
0

1
0

2
1
Protocols
Modbus RTU
Modbus TCP

NA
NA

Y
Y

Y
Y
Analog Output
4-10 mA
0-10 vdc

Y *
Y *

Requires Sentinel
or eSentry Unit
Dust Channels
Instant
Rolling Average

C
C

1
1

1
3
Alarm Monitoring
Alarm Limits
Alarm Delat

NA
NA

Y
Y

Y
Y
Auto QA Checks
EDC
RIC

N
N

O
O

O
O - Optional
* - Outputs both analog signals simultaneously
C - Choose between Instant or Rolling Average
EDC - Electronic Drift Check, includes both zero/span and linearity
RIC - Rod Isolation Check (US Patent 9482706B2)

Specifications

Parameter Scout Atlas Titan
Measurement Range Detection Limit < 0.1 mg/m3 Max Several g/m3, depending on conditions
Enclosure Stainless Steel (IP65 / Nema 4X)
Weight 7.0 lbs (3.2 kg) (without rod)
Dimensions
(W x H x D)
7" x 11" x 5" 178mm x 280mm x 127mm (without rod)
Probe Length + STD - 36" Active,  45" -Total
Probe Type + STD - Local, Remote Probe Optional
Ambient Temperature -40 C to +60 C (-40 F to 140 F)
Power Supply 24 VDC
Power Consumption Less than 5 Watts
Process Temperature + Default 200 C (392 F)
Optionally up to 1600 F (871 C)
Process Pressure Default 3000 psi (20684 kPa)
Process Humidity Max 95% RH (non-condensing)
Optional QA Checks Electronic Drift Check (EDC)
Rod Isolation Check (RIC)
+ - Custom options available
B3Sys Logo
Contact Us


Phone: +1.919.790.9090
Fax: +1.919.790.0550
Address: 3208 Spottswood St., STE 106, Raleigh, NC 27615

Copyright © B3 Systems, Inc. 2023