The Atlas dust sensor has two (2) dust channels, instantaneous and 2 rolling average channels. This is a new line... The sensor handles all of the rolling average calculations as well as all alarming functions for all dust channels, including alarm delays. Each rolling average periods and alarm setting for each channel is independently configurable. All you have to do is read the data registers.
Team the Atlas with one of our interface controllers and you have one of the most powerful compliance and diagnostic tools on the market. The Interface Controller can store and back-up data to a USB drive so you can easily grab the history to help identify process changes or use the data to EPA MACT reporting.
| Parameter | Scout | Atlas | Titan |
|---|---|---|---|
|
Measurement Principle |
Dynamic Induction | ||
| Detection Limit | < 0.1 mg/m3 | ||
| Maximum Range | Several g/m3, depending on conditions | ||
| Enclosure | Stainless Steel (IP65 / Nema 4X) | ||
| Comm Ports RS485 Ports Ethernet |
0 0 |
1 0 |
2 1 |
| Protocols Modbus RTU Modbus TCP |
NA NA |
Y Y |
Y Y |
| Analog Output 4-10 mA 0-10 vdc |
Y * Y * |
Requires Sentinel or eSentry Unit |
|
| Dust Channels Instant Rolling Average |
C C |
1 1 |
1 3 |
| Alarm Monitoring Alarm Limits Alarm Delat |
NA NA |
Y Y |
Y Y |
| Auto QA Checks EDC RIC |
N N |
O O |
O O |
| O - Optional * - Outputs both analog signals simultaneously C - Choose between Instant or Rolling Average EDC - Electronic Drift Check, includes both zero/span and linearity RIC - Rod Isolation Check (US Patent 9482706B2) |
|||
| Parameter | Scout | Atlas | Titan |
|---|---|---|---|
| Measurement Range | Detection Limit < 0.1 mg/m3 Max Several g/m3, depending on conditions | ||
| Enclosure | Stainless Steel (IP65 / Nema 4X) | ||
| Weight | 7.0 lbs (3.2 kg) (without rod) | ||
| Dimensions (W x H x D) |
7" x 11" x 5" 178mm x 280mm x 127mm (without rod) | ||
| Probe Length + | STD - 36" Active, 45" -Total | ||
| Probe Type + | STD - Local, Remote Probe Optional | ||
| Ambient Temperature | -40 C to +60 C (-40 F to 140 F) | ||
| Power Supply | 24 VDC | ||
| Power Consumption | Less than 5 Watts | ||
| Process Temperature + | Default 200 C (392 F) Optionally up to 1600 F (871 C) |
||
| Process Pressure | Default 3000 psi (20684 kPa) | ||
| Process Humidity | Max 95% RH (non-condensing) | ||
| Optional QA Checks | Electronic Drift Check (EDC) Rod Isolation Check (RIC) |
||
| + - Custom options available | |||
Phone: +1.919.790.9090
Fax: +1.919.790.0550
Address: 3208 Spottswood St., STE 106, Raleigh, NC 27615
Copyright © B3 Systems, Inc. 2023